THe HI-98318 is our latest pocket meter for measuring the EC/TDS of a hydroponic nutrient solution. This modern looking meter is only 0.7" thick and extremely ergonomic, fitting comfortably in your hand. The HI-98318 has a very large easy to read LCD display that shows both EC or TDS and temperature along with calibration, stability and low battery indicators. All operations are simplified to two buttons. One is for turning the meter on/off and the other for automatic one point calibration.
Features at-a-glance
Ordering Information: HI-98318 GroLine EC/TDS meter is supplied with protective cap, (4) HI-50036 Quick Cal Calibration Sachets (20 ml), (1) CR2032 battery, instruction manual, and quality certificate.
Accuracy EC | ±2% F.S. |
Dimensions | 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“) |
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
Range Conductivity | 0.00 to 6.00 mS/cm |
Range TDS | 0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF) |
Resolution Conductivity | 0.01 mS/cm |
Resolution TDS | 10 ppm (mg/L) |
TDS Accuracy | ±2% F.S. |
TDS Conversion Factor | 0.5 (500 ppm) or 0.7 (700 ppm) |
Temperature Accuracy | ±0.5°C /±1°F |
Temperature Compensation | automatic from 0 to 50°C (32 to 122°F) |
Temperature Range | 0.0 to 50.0°C / 32.0 to 122.0°F |
Temperature Resolution | 0.1°C / 0.1°F |
Weight | 75 g (2.6 oz.) |
Tuote lisätty ostoskoriin! Siirry tästä ostoskoriin ▶
THe HI-98318 is our latest pocket meter for measuring the EC/TDS of a hydroponic nutrient solution. This modern looking meter is only 0.7" thick and extremely ergonomic, fitting comfortably in your hand. The HI-98318 has a very large easy to read LCD display that shows both EC or TDS and temperature along with calibration, stability and low battery indicators. All operations are simplified to two buttons. One is for turning the meter on/off and the other for automatic one point calibration.
Features at-a-glance
Ordering Information: HI-98318 GroLine EC/TDS meter is supplied with protective cap, (4) HI-50036 Quick Cal Calibration Sachets (20 ml), (1) CR2032 battery, instruction manual, and quality certificate.
Accuracy EC | ±2% F.S. |
Dimensions | 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“) |
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
Range Conductivity | 0.00 to 6.00 mS/cm |
Range TDS | 0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF) |
Resolution Conductivity | 0.01 mS/cm |
Resolution TDS | 10 ppm (mg/L) |
TDS Accuracy | ±2% F.S. |
TDS Conversion Factor | 0.5 (500 ppm) or 0.7 (700 ppm) |
Temperature Accuracy | ±0.5°C /±1°F |
Temperature Compensation | automatic from 0 to 50°C (32 to 122°F) |
Temperature Range | 0.0 to 50.0°C / 32.0 to 122.0°F |
Temperature Resolution | 0.1°C / 0.1°F |
Weight | 75 g (2.6 oz.) |
Myymälä Äänekoski, Teollisuuskatu 45, 44150
Ma: 09.00-16.00
Ti: 09.00 - 16.00
Ke: 09.00 - 16.00
To: 09.00 - 16.00
Pe: 09.00 - 16.00
Muina aikoina sopimuksen mukaan, kysy asiakaspalvelusta.
Myymälä Oulu, Kaarnatie 22, 90530
Ma: 11.00-17.00
Ti: 11.00 - 17.00
Ke: 11.00 - 17.00
To: 11.00 - 17.00
Pe: 11.00 - 17.00